2-conductor fuse terminal block; with pivoting fuse holder; and end plate; for 5 x 20 mm miniature metric fuse; without blown fuse indication; for DIN-rail 35 x 15 and 35 x 7.5; 2.5 mm2; Push-in CAGE CLAMP?; 2,50 mm2; orange
起订量
1最小包装量--
请发送询价,我们将立即回复。
2002-1612详情
技术参数
wago 2002-1612重要参数规格及、参数值,及相似型号如下:
- 参数名参数值全选
- 参数名参数值全选
Mounting type
DIN-35 rail
质量
13.2g
Clamping units
2
Total number of potentials
1
Number of jumper slots
2
Depth from upper-edge of DIN-rail
57.2 mm / 2.252 inches
Marking level
Center/side marking
Note (material data)
Information on material specifications can be found here
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.233MJ
Processing temperature
-35 … +85 °C
Continuous operating temperature
-60 … +105 °C
ETIM 9.0
EC000899
ETIM 8.0
EC000899
ECCN
NO US CLASSIFICATION
PU (SPU)
50 pcs
Packaging type
Box
Country of origin
DE
GTIN
4055143870979
Customs tariff number
85369095000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
ATEX: KIWA 17 ATEX 0030 U / IECEx: KIWA 17.0014U (Ex ec IIC Gc)
Rated voltage (III / 3)
250V
Rated impulse voltage (III / 3)
6kV
Legend (ratings)
(III / 3) ? Overvoltage category III / Pollution degree 3
Ratings (note)
Electrical ratings are given by the fuse.
Approvals per
CSA 22.2 No 158
Rated voltage UL (Use Group B)
250V
Rated current UL (Use Group B)
10A
Rated voltage UL (Use Group C)
250V
Rated current UL (Use Group C)
10A
Rated voltage UL (Use Group D)
250V
Rated current UL (Use Group D)
10A
Rated voltage CSA (Use Group B)
250V
Rated current CSA (Use Group B)
6.3A
Rated voltage CSA (Use Group C)
250V
Rated current CSA (Use Group C)
6.3A
Reference hazardous areas
See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
Rated voltage EN (Ex e II)
275V
Rated current (Ex e II)
6.3A
Power loss (max.) P<sub>l (max.)</sub> (note)
When selecting glass cartridge fuses, make sure that the maximum power loss listed below is not exceeded. The power loss is determined according to IEC or EN 60947-7-3/VDE 0611-6 at 23°C. The temperature rise of the terminal block must be checked according to their application and mounting. Higher ambient temperatures represent an additional impact on miniature fuses. Therefore, in such applications, the rated current must be reduced if necessary. More details are available from the manufacturers.
Power loss P<sub>l</sub> max. overload and short-circuit protection (individual arrangement)
1.6W
Power loss P<sub>l</sub> max. overload and short-circuit protection (group arrangement)
1.6W
Power loss P<sub>l</sub> max. short-circuit protection (individual arrangement)
2.5W
Power loss P<sub>l</sub> max. short-circuit protection (group arrangement)
2.5W
Fuse receptacle
pivoting
Connection technology
Push-in CAGE CLAMP?
Actuation type
Operating tool
Connectable conductor materials
Copper
Nominal cross-section
2.5 mm2
Solid conductor
0.25 … 4 mm2 / 22 … 12 AWG
Solid conductor; push-in termination
0.75 … 4 mm2 / 18 … 12 AWG
Fine-stranded conductor
0.25 … 4 mm2 / 22 … 12 AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 2.5 mm2 / 22 … 14 AWG
Fine-stranded conductor; with ferrule; push-in termination
1 … 2.5 mm2 / 18 … 14 AWG
Note (conductor cross-section)
Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length
10 … 12 mm / 0.39 … 0.47 inches
Wiring direction
Front-entry wiring
颜色
orange
Number of levels
1
Fuse type
Cylindrical fuse; 5 x 20 mm
Rated current
6.3A
宽度
6.2 mm / 0.244 inches
高度
66.1 mm / 2.602 inches