2202-1912/1000-867
2202-1912/1000-867

注:图像仅供参考,请参阅产品规格

技术文档 技术文档

PDF列表 PDF文档列表
免费送样

wago 2202-1912/1000-867

  • 收藏
  • 对比

型号

2202-1912/1000-867

品牌

wago

utmel 编号

2685-2202-1912/1000-867

商品类别

无类别的

封装

--

交货地

大陆

交期(工作日)

立即发货

ROHS

ECAD

简介

2-conductor fuse terminal block; with pivoting fuse holder; with additional jumper position; for 5 x 20 mm miniature metric fuse; with push-button; with blown fuse indication by LED; 120 V; for DIN-rail 35 x 15 and 35 x 7.5; 2.5 mm2; Push-in CAGE CLAMP?; 2,50 mm2; orange

起订量

1最小包装量--

添加到询价列表
2202-1912/1000-867
2202-1912/1000-867 wago 2-conductor fuse terminal block; with pivoting fuse holder; with additional jumper position; for 5 x 20 mm miniature metric fuse; with push-button; with blown fuse indication by LED; 120 V; for DIN-rail 35 x 15 and 35 x 7.5; 2.5 mm2; Push-in CAGE CLAMP?; 2,50 mm2; orange

请发送询价,我们将立即回复。

库存:

请发送询价,我们将立即回复。

*
验证码
在线咨询

2202-1912/1000-867详情

wago 2202-1912/1000-867重要参数规格及、参数值,及相似型号如下:

  • 参数名
    参数值
    全选
  • 参数名
    参数值
    全选
  • Mounting type

    DIN-35 rail

  • 质量

    14.5g

  • Clamping units

    2

  • Total number of potentials

    1

  • Number of jumper slots

    3

  • Depth from upper-edge of DIN-rail

    57.6?mm?/ 2.268?inches

  • Marking level

    Center/side marking

  • Note (material data)

    Information on material specifications can be found here

  • Material group

    I

  • Insulation material (main housing)

    Polyamide (PA66)

  • Flammability class per UL94

    V0

  • Fire load

    0.319MJ

  • ActuatorColor

    orange

  • Processing temperature

    -35 … +85?°C

  • Continuous operating temperature

    -60 … +105?°C

  • ETIM 9.0

    EC000899

  • ETIM 8.0

    EC000899

  • ECCN

    NO US CLASSIFICATION

  • PU (SPU)

    50?pcs

  • Packaging type

    Box

  • Country of origin

    DE

  • GTIN

    4066966313314

  • Customs tariff number

    85369095000

  • CAS-No.

    1303-86-2

  • REACH Candidate List Substance

    Diboron trioxide

  • RoHS Compliance Status

    Compliant,With Exemption

  • RoHS Exemption

    7(a)

  • SCIP notification number (Austria)

    cd67e6d6-66ed-4087-b124-6e6e617bb56a

  • SCIP notification number (Belgium)

    2d2e24bd-35c2-446b-a241-403d568baf25

  • SCIP notification number (Czech Republic)

    ed069561-57db-45ef-8cd8-231ed4682a72

  • SCIP notification number (Denmark)

    24519d87-18b8-4e00-9dbc-5d7af4ad7e81

  • SCIP notification number (Finland)

    8153f749-aaa1-413a-990d-a5275547f73a

  • SCIP notification number (Germany)

    5541652a-9e42-4380-876b-9d88e48c5ce4

  • SCIP notification number (Netherlands)

    5d46a4e3-d7dc-4713-9079-bb631ad6b927

  • SCIP notification number (Poland)

    669f87b9-aa16-4f54-a2e6-265ee036bad8

  • SCIP notification number (Romania)

    8c1bdb28-14b0-40ec-9541-3b5743fdf217

  • SCIP notification number (Sweden)

    743a6692-71fe-46d3-a57e-1ec273b74c94

  • Ratings per

    ATEX: PTB 20 ATEX 1007 U / IECEx: PTB 20.0013U (Ex ec IIC Gc)

  • Rated voltage (III / 3)

    250V

  • Rated impulse voltage (III / 3)

    6kV

  • Blown fuse indication

    120 V

  • Legend (ratings)

    (III / 3) ? Overvoltage category III / Pollution degree 3

  • Ratings (note)

    Electrical ratings are given by the fuse and blown fuse indication.

  • Rated current (note)

    Leakage current in case of a blown fuse: LED 2 mA

  • Approvals per

    CSA 22.2 No 158

  • Rated voltage UL (Use Group B)

    120V

  • Rated current UL (Use Group B)

    10A

  • Rated voltage UL (Use Group C)

    120V

  • Rated current UL (Use Group C)

    10A

  • Rated voltage UL (Use Group D)

    120V

  • Rated voltage CSA (Use Group B)

    120V

  • Rated current CSA (Use Group B)

    10A

  • Rated voltage CSA (Use Group C)

    120V

  • Rated current CSA (Use Group C)

    10A

  • Rated voltage CSA (Use Group D)

    120V

  • Rated current CSA (Use Group D)

    10A

  • Reference hazardous areas

    See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications”

  • Rated voltage EN (Ex e II)

    275V

  • Rated current (Ex e II)

    6.3A

  • Power loss P<sub>l</sub> max. overload and short-circuit protection (individual arrangement)

    1.6W

  • Power loss P<sub>l</sub> max. overload and short-circuit protection (group arrangement)

    1.6W

  • Power loss P<sub>l</sub> max. short-circuit protection (individual arrangement)

    2.5W

  • Power loss P<sub>l</sub> max. short-circuit protection (group arrangement)

    2.5W

  • Fuse receptacle

    pivoting

  • Connection technology

    Push-in CAGE CLAMP?

  • Actuation type

    Push-button

  • Connectable conductor materials

    Copper

  • Nominal cross-section

    2.5 mm2

  • Solid conductor

    0.25 … 4?mm2?/ 22 … 12?AWG

  • Solid conductor; push-in termination

    0.75 … 4?mm2?/ 18 … 12?AWG

  • Fine-stranded conductor

    0.25 … 4?mm2?/ 22 … 12?AWG

  • Fine-stranded conductor; with insulated ferrule

    0.25 … 2.5?mm2?/ 22 … 14?AWG

  • Fine-stranded conductor; with ferrule; push-in termination

    1 … 2.5?mm2?/ 18 … 14?AWG

  • Note (conductor cross-section)

    Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.

  • Strip length

    10 … 12?mm?/ 0.39 … 0.47?inches

  • Wiring direction

    Front-entry wiring

  • 颜色

    orange

  • Number of levels

    1

  • Fuse type

    Cylindrical fuse; 5 x 20 mm

  • Rated current

    6.3A

  • 宽度

    6.2?mm?/ 0.244?inches

  • 高度

    72.9?mm?/ 2.87?inches

0个相似型号

2202-1912/1000-867拓展信息

索引: # 0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

公司资质

ISO13485
AS
SMTA
DUNS