wago 734-314/109-000
- 收藏
- 对比
型号
734-314/109-000
品牌
utmel 编号
2685-734-314/109-000
商品类别
无类别的
封装
--
交货地
大陆
交期(工作日)
立即发货
ROHS

简介
1-conductor male connector; CAGE CLAMP?; 1.5 mm2; Pin spacing 3.5 mm; 14-pole; 100% protected against mismating; Threaded flange; 1,50 mm2; light gray
起订量
1最小包装量--
请发送询价,我们将立即回复。
734-314/109-000详情
技术参数
PDF文档
wago 734-314/109-000重要参数规格及、参数值,及相似型号如下:
- 参数名参数值全选
- 参数名参数值全选
Contact plating
Tin
质量
12g
Safety information
TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants
Other pole numbers
Clamping units
14
Total number of potentials
13
Number of connection types
1
Pin spacing
3.5?mm?/ 0.138?inches
Variable coding
有
Anti-rotation protection
有
Contact type (pluggable connector)
Male connector/plug
Connector (connection type)
for conductor
Mismating protection
有
Plugging without loss of pin spacing
无
Locking of plug-in connection
Threaded flange
Note (material data)
Information on material specifications can be found here
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Clamping spring material
Chrome-nickel spring steel (CrNi)
Contact Materials
Electrolytic copper (ECu)
Fire load
0.221MJ
Limit temperature range
-60 … +100?°C
Processing temperature
-35 … +60?°C
Product Group
3 (Multi Conn. System)
eCl@ss 10.0
27-44-03-09
eCl@ss 9.0
27-44-03-09
ETIM 9.0
EC002638
ETIM 8.0
EC002638
ECCN
NO US CLASSIFICATION
PU (SPU)
25?pcs
Packaging type
box
Country of origin
DE
GTIN
4055143265324
Customs tariff number
85366930000
CAS-No.
7439-92-1
REACH Candidate List Substance
Lead
RoHS Compliance Status
Compliant,With Exemption
RoHS Exemption
6(c)
SCIP notification number (Austria)
e47363a1-16a0-4fec-a414-1bb52443c7e6
SCIP notification number (Belgium)
76150317-3e01-4bc4-9274-3a822e3bf77b
SCIP notification number (Bulgaria)
fc3bdfd2-dc19-4b01-a14a-bff97c6cbf60
SCIP notification number (Czech Republic)
a880c9a1-e5b3-4a09-a45c-e5f0c97f5603
SCIP notification number (Denmark)
e493b9e5-260b-4493-b122-c679fcda8fd5
SCIP notification number (Finland)
83cdc43f-df59-4965-b846-881d07c02dea
SCIP notification number (France)
9743be3e-b25d-4457-93b3-96bae0288bc2
SCIP notification number (Germany)
fa862a42-ccfe-4226-a7af-416af9463b05
SCIP notification number (Hungary)
a6693845-f5b5-4069-adfb-4256f020cdfc
SCIP notification number (Italy)
9d5ac24e-6638-4ec3-8fa3-96d5147f875d
SCIP notification number (Netherlands)
4aed1d42-1b22-4c05-b73d-3ac6dffe10ef
SCIP notification number (Poland)
8fef20b3-c06e-430a-a791-764ce506e208
SCIP notification number (Romania)
164336ae-310f-4134-a140-e6270b5580a6
SCIP notification number (Sweden)
a58185f0-b52d-4163-98d1-ace5d719f5ad
Ratings per
IEC/EN 60664-1
Rated voltage (III / 3)
160V
Rated impulse voltage (III / 3)
2.5kV
Rated voltage (III/2)
160V
Rated surge voltage (III/2)
2.5kV
Nominal voltage (II/2)
320V
Rated surge voltage (II/2)
2.5kV
Legend (ratings)
(III / 2) ? Overvoltage category III / Pollution degree 2
Approvals per
CSA
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
10A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
10A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
10A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Connection technology
CAGE CLAMP?
Actuation type
Operating tool
Actuation direction 1
Operation parallel to conductor entry
Actuation direction 2
Operation perpendicular to conductor entry
Solid conductor
0.08 … 1.5?mm2?/ 28 … 14?AWG
Fine-stranded conductor
0.08 … 1.5?mm2?/ 28 … 14?AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 1.5?mm2
Fine-stranded conductor; with uninsulated ferrule
0.25 … 1.5?mm2
Note (conductor cross-section)
Terminating 1.5 mm2 conductors is possible; however insulation diameter does not allow clamping units to be terminated in a row.
Strip length
6 … 7?mm?/ 0.24 … 0.28?inches
Conductor entry direction to mating direction
0°
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed
颜色
light gray
深度
22.3?mm?/ 0.878?inches
频率
f1= 5 Hz to f2= 150 Hz
Number of levels
1
Number of poles
13
Rated current
10A
宽度
58.5?mm?/ 2.303?inches
高度
13.4?mm?/ 0.528?inches